You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/11085
Title: 
Estudo mecânico da estabilidade dorsal da osteossíntese intramedular associada à fixação externa (método de Ulson)
Other Titles: 
Mechanical study on dorsal stability of intramedullary osteosynthesis associated with external fixation (Ulson's method)
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0102-3616
Abstract: 
  • OBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.
  • OBJECTIVE: To evaluate the Ulson intramedullary fixation method, with external fixation in which the level of the external locking of the Kirschner wires is varied, and without external fixation. METHODS: Eighteen porcine tibias were used. Transverse osteotomy was performed in the region of the tuberosity, and two intramedullary Kirschner wires were inserted into each specimen, using three different assembly patterns: Group I: locking with external minifixator at a height of 3.0 cm; Group II: locking at a height of 4.5 cm; Group III: without external locking. Mechanical shear tests were then conducted, to determine the maximum load, proportionality limit and coefficient of rigidity. RESULTS: There were no significant differences in maximum load or proportionality limit between the groups. The coefficient of rigidity was higher in Group II. CONCLUSION: The locking height for the Kirschner wires in Ulson's method, within the limits evaluated, did not harm the stability of the fracture fixation system.
Issue Date: 
1-Jan-2011
Citation: 
Revista Brasileira de Ortopedia. Sociedade Brasileira de Ortopedia e Traumatologia, v. 46, n. 6, p. 656-659, 2011.
Time Duration: 
656-659
Publisher: 
Sociedade Brasileira de Ortopedia e Traumatologia
Keywords: 
  • Fraturas do Rádio
  • Fixadores Externos
  • Biomecânica
  • Radius Fractures
  • External Fixators
  • Biomechanics
Source: 
http://dx.doi.org/10.1590/S0102-36162011000600006
URI: 
http://hdl.handle.net/11449/11085
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/11085
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.