You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/12680
Title: 
Avaliação quantitativa das dimensões óculo-palpebrais em portadores de cavidade anoftálmica em uso de prótese ocular externa
Other Titles: 
Quantitative eyelid evaluation of anophthalmic cavity carriers with external ocular prosthesis
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0004-2749
Abstract: 
  • OBJETIVOS: Avaliar o posicionamento palpebral em portadores de cavidade anoftálmica com e sem prótese ocular externa, utilizando o processamento de imagem digital. MÉTODOS: Dezoito pacientes foram avaliados qualitativa e quantitativamente na Faculdade de Medicina de Botucatu - Universidade Estadual Paulista - UNESP, com e sem a prótese externa. Usando imagens obtidas por filmadora e processadas usando o programa Scion Image, mediu-se a altura do sulco palpebral superior, a altura da fenda palpebral e os ângulos palpebrais dos cantos interno e externo. RESULTADOS: Pseudo-estrabismo e sulco palpebral superior profundo foram as alterações mais freqüentes ao exame externo. Houve diferença significativa em todas as variáveis estudadas, com diminuição da altura do sulco palpebral superior, aumento da área da fenda palpebral e aumento dos ângulos palpebrais interno e externo quando o paciente estava usando a prótese externa. CONCLUSÃO: Todos os pacientes avaliados apresentaram algum tipo de anormalidade órbito-palpebral, o que reflete a dificuldade em se proporcionar ao portador de cavidade anoftálmica um aspecto idêntico ao que existe na órbita normal. O processamento de imagens digitais permitiu avaliação objetiva das dimensões óculo-palpebrais, o que poderá contribuir nas avaliações seqüenciais dos portadores de cavidade anoftálmica.
  • PURPOSE: The authors intend to evaluate the eyelid position before and after the external prosthesis adaptation, using digital image processing techniques. METHODS: Eighteen patients were evaluated at the Faculdade de Medicina de Botucatu - Universidade Estadual Paulista - UNESP, with and without the external prosthesis. Qualitative and quantitative analysis were done using the Scion Image program. The superior eyelid sulcus distance, margin eyelid distance and eyelid medial and lateral canthus angles were evaluated. RESULTS: Pseudostrabismus and high eyelid sulcus were the most observed alteration. The superior eyelid sulcus distance had shorter values with the prosthesis and higher values were seen analyzing the other parameters when the external prosthesis was in place. CONCLUSION: All patients had some abnormalities, which show us how difficult it is to provide a normal aspect for anophthalmic cavity carriers. The image processing allowed objective evaluations of the measures contributing to the follow-up of the patients.
Issue Date: 
1-Aug-2005
Citation: 
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 68, n. 4, p. 517-520, 2005.
Time Duration: 
517-520
Publisher: 
Conselho Brasileiro de Oftalmologia
Keywords: 
  • Doença de Graves
  • Blefaroptose
  • Enucleação ocular
  • Doenças palpebrais
  • Orbita
  • Processamento de imagem assistida por computador
  • Próteses e implantes
  • Síndrome
  • Graves' disease
  • Blepharoptosis
  • Eye Enucleation
  • Eyelid diseases
  • Orbit
  • Image processing, computer-assisted
  • Prostheses and implants
  • Syndrome
Source: 
http://dx.doi.org/10.1590/S0004-27492005000400017
URI: 
http://hdl.handle.net/11449/12680
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/12680
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.