You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/14751
Title: 
PCR Multiplex fluorescente para detecção de bactérias em sêmen bovino
Other Titles: 
Fluorescent Multiplex PCR for detection of bacteria in semen bovine
Author(s): 
Institution: 
  • Universidade Federal do Tocantins (UFT)
  • Universidade Estadual Paulista (UNESP)
ISSN: 
0100-736X
Abstract: 
  • Este estudo teve como objetivo avaliar o limiar de detecção da técnica de PCR multiplex fluorescente aliada a eletroforese capilar na detecção de agentes infecciosos em amostras de sêmen experimentalmente contaminadas com concentrações decrescentes das bactérias Brucella abortus, Leptospira interrogans sorovar pomona, Campylobacter fetus e Haemophilus somnus. Amostras de sêmen bovino foram experimentalmente contaminadas com concentrações decrescentes de bactérias obtidas através de diluições seriadas na base 10 de modo a obter-se amostras contendo desde 1 vez até 10-7 bactérias/mL a partir da concentração inicial de Leptospira pomona, Brucella abortus, Campylobacter fetus e Haemophilus somnus. As diluições foram efetuadas individualmente para cada bactéria, bem como nas diferentes concentrações necessárias para a padronização do teste de multiplex PCR. As extrações de DNA de todas as soluções contendo espermatozóides e bactérias analisadas no presente estudo foram realizadas segundo protocolo descrito por Heinemann et al. (2000). Os produtos de PCR multiplex foram avaliados por eletroforese em gel de poliacrilamida 8% e separação eletroforética por sistema capilar em equipamento automático de análise de fragmentos de DNA MegaBace. Observou-se a amplificação de fragmentos de 193pb, 330pb, 400pb e 415pb a partir do DNA de B. abortus, L. pomona, H. somnus, C. fetus, respectivamente. Na análise por eletroforese capilar de produtos da PCR multiplex do DNA para detecção simultânea dos quatro patógenos observou-se a sinal de positividade até a diluição de 10-3 bactérias/mL vezes da concentração inicial da solução estoque de cada bactéria. A técnica de PCR multiplex aliada à eletroforese capilar foi usada pela primeira vez para o diagnóstico direto de quatro bactérias patogênicas no sêmen, demonstrando ser um método rápido na detecção de bactérias causadoras de doenças reprodutivas.
  • This study aimed to evaluate the threshold of detection of fluorescent multiplex PCR coupled with capillary electrophoresis for detection of infectious agents in semen samples from experimentally infected with decreasing concentrations of the bacteria Brucella abortus, Leptospira interrogans serovar pomona, Campylobacter fetus and Haemophilus somnus. Samples of bovine semen were experimentally infected with decreasing concentrations of bacteria obtained from serial dilutions in the base 10 so as to obtain samples containing a long time until 10-7 bacteria/mL from the initial concentration of Lepstospira pomona, Brucella abortus, Haemophilus somnus and Campylobacter fetus. The dilutions were made individually for each bacterium, as well as in different concentrations needed to standardize the multiplex PCR test. DNA extractions of all solutions containing sperm and bacteria analyzed in this study were performed according to protocol described by Heinemann et al. (2000). The multiplex PCR products were analyzed by electrophoresis on 8% polyacrylamide gel and capillary electrophoretic separation system for automated equipment in the analysis of DNA fragments MegaBACE. We observed amplification of fragments of 193pb, 330pb, 415pb and 400bp from the DNA of B. abortus, L. pomona, H. somnus, C. fetus respectively. The analysis by capillary electrophoresis of multiplex PCR products of DNA for simultaneous detection of the four pathogens was observed by detecting the dilution of 10-3 bacteria / mL times the initial concentration of the stock solution of each bacterium. The multiplex PCR coupled with capillary electrophoresis was first used for the direct diagnosis of four pathogenic bacteria in semen, proving to be a rapid method to detect bacteria that cause reproductive disorders.
Issue Date: 
1-Mar-2012
Citation: 
Pesquisa Veterinária Brasileira. Colégio Brasileiro de Patologia Animal - CBPA, v. 32, n. 3, p. 211-216, 2012.
Time Duration: 
211-216
Publisher: 
Colégio Brasileiro de Patologia Animal - CBPA
Keywords: 
  • Bovino
  • sêmen
  • bactérias
  • diagnóstico
  • PCR fluorescente
  • eletroforese capilar
  • Cattle
  • semen
  • bacteria
  • diagnosis
  • fluorescent PCR
  • capillary electrophoresis
Source: 
http://dx.doi.org/10.1590/S0100-736X2012000300005
URI: 
http://hdl.handle.net/11449/14751
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/14751
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.