You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15359
Title: 
Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1059-9495
Sponsorship: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Sponsorship Process Number: 
  • FAPESP: 07/53140-3
  • FAPESP: 07/04181-9
Abstract: 
The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 12): Gold UCLA abutments cast in gold alloy veneered with ceramic (Group I) and resin (Group II), UCLA abutments cast in titanium veneered with ceramic (Group III) and resin (Group IV), and zirconia abutments with ceramic veneering (Group V). The crowns were attached to implants by gold retention screws with 35-N cm insertion torque. Specimens were submitted to mechanical cycling up to 10(6) cycles. Measurements of detorque and vertical misfit in abutment-implant interface were performed before and after mechanical cycling. ANOVA revealed statistically significant difference (P < 0.05) among groups for vertical misfit measured before and after mechanical cycling. The abutments cast in titanium exhibited the highest misfit values. Pearson correlation test did not demonstrate significant correlation (P > 0.05) between vertical misfit and detorque value. It was concluded that vertical misfit did not influence torque maintenance and the abutments cast in titanium exhibited the highest misfit values.
Issue Date: 
1-Aug-2011
Citation: 
Journal of Materials Engineering and Performance. New York: Springer, v. 20, n. 6, p. 947-951, 2011.
Time Duration: 
947-951
Publisher: 
Springer
Keywords: 
  • casting
  • material selection
  • opticalmicroscopy
  • titanium
Source: 
http://dx.doi.org/10.1007/s11665-010-9699-9
URI: 
http://hdl.handle.net/11449/15359
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/15359
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.