You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15793
Title: 
Estudo qualitativo fotoelástico do sistema de forças gerado pela mola T de retração com diferentes pré-ativações
Other Titles: 
Qualitative photoelastic study of the force system produced by retraction T-springs with different preactivations
Author(s): 
Institution: 
  • Universidade Tiradentes
  • Universidade Estadual Paulista (UNESP)
  • Universidade Federal de Uberlândia (UFU)
  • Baylor College of Dentistry Departamento de Ortodontia
ISSN: 
2176-9451
Abstract: 
  • OBJETIVO: avaliar o sistema de forças gerado pela mola T utilizada para fechamento de espaços. MÉTODOS: por meio do método experimental fotoelástico, avaliou-se a mola T utilizada no fechamento de espaços com duas variações de pré-ativação em sua porção apical, sendo uma com 30º e a outra com 45º. As molas foram confeccionadas com fio retangular de titânio-molibdênio (TMA) de secção 0,017 x 0,025, centralizadas no espaço interbraquetes de 27mm e ativadas em 5,0mm, 2,5mm e posição neutra. Para melhor confiabilidade dos resultados, os testes foram repetidos em três modelos fotoelásticos igualmente reproduzidos e confeccionados pelo mesmo operador. Para compreensão dos resultados, as franjas fotoelásticas visualizadas no polariscópio foram fotografadas e analisadas qualitativamente. RESULTADOS: por meio da análise qualitativa da ordem de franjas no modelo fotoelástico, notou-se que, nas extremidades de retração e ancoragem, a mola T com 30º de ativação apical apresentou um acúmulo de energia discretamente maior para o sistema de forças liberado.
  • OBJECTIVE: Evaluate the force system produced by the T-spring used for space closure. METHODS: By means of the experimental photoelastic method, we evaluated the T-spring-used for space closure-with two different preactivations on its apical portion, i.e., one with 30° and one with 45º. The springs were fabricated with rectangular 0.017 X 0.025-in titanium-molybdenum alloy (TMA), centered in a 27.0 mm interbracket space and activated at 5.0 mm and 2.5 mm, and in a neutral position. For more reliable results, tests were repeated on three photoelastic models duplicated and prepared by the same operator. To better understand the results, the fringes seen in the polariscope were photographed and analyzed qualitatively. RESULTS: Through qualitative analysis of the fringe order in the photoelastic model it was noted that at the retraction and anchoring ends the T-spring with 30° apical activation showed a slightly greater accumulation of energy relative to the force system that was generated.
Issue Date: 
1-Aug-2010
Citation: 
Dental Press Journal of Orthodontics. Dental Press International, v. 15, n. 4, p. 103-116, 2010.
Time Duration: 
103-116
Publisher: 
Dental Press International
Keywords: 
  • Fechamento de espaço ortodôntico
  • Mola T
  • Estudo fotoelástico
  • Retração
  • Closing of orthodontic space
  • T loop
  • Photoelastic study
  • Retraction
Source: 
http://dx.doi.org/10.1590/S2176-94512010000400015
URI: 
http://hdl.handle.net/11449/15793
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/15793
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.