You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/1815
Title: 
Técnica para avaliação da pressão arterial pulmonar de equinos durante o exercício progressivo em esteira rolante
Other Titles: 
Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Centro Universitário Cesmac Fundação Educacional Jayme de Altavila
ISSN: 
0100-736X
Sponsorship: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Abstract: 
  • Objetivou-se ilustrar a técnica cirúrgica de implantação de introdutores para cateter de Swan Ganz na veia jugular, bem como o procedimento de canulação da artéria pulmonar de dez equinos adultos sem raça definida (SRD). Realizando medidas através do cateter de Swan Ganz implantado, objetivou-se ainda demonstrar os valores de pressão arterial pulmonar (PAP) durante um teste de esforço progressivo de intensidade submáxima realizado em esteira rolante. A técnica cirúrgica de implantação de introdutores para o cateter de Swan Ganz empregada, demonstrou-se de fácil e rápida realização. Os animais não apresentaram complicações frente ao introdutor implantado e o teste ergométrico foi realizado conforme proposto. A PAP se elevou ao longo do exercício seguindo o incremento de velocidade, sendo os maiores valores médios observados nos momentos de maior intensidade do esforço. Os valores médios de PAP aumentaram (p<0,05) às velocidades de 7,5m/s (39±3 mmHg) e 8,5m/s (41±3 mmHg), quando comparados aos valores mensurados no repouso (26±3mmHg). Entretanto, os valores de PAP encontrados no máximo de esforço realizado pelos equinos SRD deste ensaio (41±3mmHg), encontram-se abaixo dos valores descritos para outras raças para a mesma intensidade de esforço. A descrição detalhada da técnica ilustrada no presente trabalho, pode contribuir substancialmente na padronização de protocolos experimentais que propõem o acesso arterial pulmonar por meio da implantação de cateter de Swan Ganz em equinos. O teste ergométrico proposto foi eficaz em promover variações de PAP de acordo com o esforço realizado, demonstrando valores para equinos SRD que poderão ser usados como base para futuras avaliações.
  • The aim of this study was to illustrate the surgical implantation of Swan Ganz introducers into the jugular vein, as well as the pulmonary artery cannulation procedure using ten mixed breed (MB) adult horses. We also proposed to demonstrate pulmonary arterial pressure (PAP) values measured through the implanted Swan Ganz during one incremental submaximal exercise test performed on a treadmill. Surgical implantation of the Swan Ganz introducers has demonstrated to be easy and quick to perform. None of the animals showed signs of discomfort following the surgery and ergometric test was carried out as proposed. PAP increased proportionally with exercise intensity, and the major average values were recorded at the higher effort time points. The PAP average values increased (P<0.05) when treadmill speed reached 7.5m/s (39±3mmHg) and 8.5m/s (41±3mmHg), comparing to average values at rest (26±3mmHg). However, the PAP values observed at the maximal effort performed by the MB horses of this trial (41±3mmHg), are under the values described for other breeds at similar effort tests. The technique described in the present study contributes for the standardization of research protocols using arterial pulmonary access via Swan Ganz catheter implantation in horses. The ergometric test was effective to promote PAP changes according to the effort, showing PAP values for MB horses that can guide further investigations.
Issue Date: 
1-Feb-2013
Citation: 
Pesquisa Veterinária Brasileira. Colégio Brasileiro de Patologia Animal - CBPA, v. 33, n. 2, p. 254-260, 2013.
Time Duration: 
254-260
Publisher: 
Colégio Brasileiro de Patologia Animal - CBPA
Keywords: 
  • Exercise
  • Horse
  • pulmonary arterial pressure
  • Swan Ganz
  • Treadmill
  • Equino
  • Esteira rolante
  • exercício
  • pressão arterial pulmonar
  • Swan Ganz
Source: 
http://dx.doi.org/10.1590/S0100-736X2013000200020
URI: 
http://hdl.handle.net/11449/1815
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/1815
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.