Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano
Other Titles: 
(Laboratory scale) assessment of electrolytic processing of effluent from a urban sewage stabilization lagoon
Author(s): 
Institution: 
  • Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
  • Universidade Estadual Paulista (UNESP)
  • Universidade Estadual do Norte do Paraná (UENP)
ISSN: 
0100-4042
Abstract: 
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of salt. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of salt, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Issue Date: 
1-Jan-2010
Citation: 
Química Nova. Sociedade Brasileira de Química, v. 33, n. 3, p. 557-561, 2010.
Time Duration: 
557-561
Publisher: 
Sociedade Brasileira de Química
Keywords: 
  • electrolysis
  • treatment of effluent
  • disinfection
Source: 
http://dx.doi.org/10.1590/S0100-40422010000300012
URI: 
http://hdl.handle.net/11449/20095
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/20095
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.