You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/20688
Title: 
Influência das cargas selecionadas na determinação da potência crítica determinada no ergômetro de braço em dois modelos lineares
Other Titles: 
Effect of selected loads on the critical power determination in the arm ergometer by two linear models
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1517-8692
Abstract: 
  • O objetivo deste estudo foi verificar o efeito da seleção das cargas e do modelo utilizado para a determinação da PC no ergômetro de braço. Participaram do estudo oito voluntários do sexo masculino, que praticavam atividade física regularmente e eram aparentemente saudáveis. Os sujeitos realizaram quatro testes com cargas constantes mantidas até a exaustão voluntária no ergômetro de braço UBE 2462-Cybex. As cargas foram individualmente selecionadas para induzir a fadiga entre 1 e 15 minutos. Para cada sujeito, a determinação da PC foi realizada através de dois modelos lineares: potência-1/tempo e trabalho-tempo. em cada um dos modelos, foram utilizadas todas as potências (1), as três maiores (2) e as três menores (3). As PC encontradas no modelo potência-1/tempo e trabalho-tempo para a condição 3 (177,5 + 29,5; 173,9 + 33,3, respectivamente) foram significantemente menores do que as da condição 2 (190,5 + 23,2; 183,4 + 22,3, respectivamente), não existindo diferenças destas com as da condição 1 (184,2 + 25,4; 176,4 + 28,8, respectivamente). As PC determinadas no modelo potência-1/tempo para as condições 1 e 2 foram significantemente maiores do que as determinadas no modelo trabalho-tempo, não existindo diferenças para a condição 3. Pode-se concluir que as cargas selecionadas e o modelo utilizado interferem na determinação da PC encontrada no ergômetro de braço, podendo interferir no tempo de exaustão durante o exercício submáximo realizado em cargas relativas a este índice.
  • The aim of this study was to verify the effect of selected loads and the model used to determine CP in the arm ergometer. Eight active males apparently healthy participated in the study. The subjects performed 4 tests with constant loads maintained until the voluntary exhaustion in the arm ergometer (UBE 2462-Cybex). The loads were individually selected to induce fatigue between 1 and 15 minutes. For each subject, the determination of CP was accomplished by two linear models: power-1/time and work-time. In each model, the CP was calculated using: all power outputs (1), the three highest (2), and the three lowest outputs (3). The CP in the power-1/time and work-time models for the condition 3 (177.5 + 29.5; 173.9 + 33.3, respectively) were lower than for the condition 2 (190.5 + 23.2; 183.4 + 22.3, respectively), no difference existing between condition 2 and 1 (184.2 + 25.4; 176.4 + 28.8, respectively). The CP determined in the power-1/time model for conditions 1 and 2 were higher than in the work-time model, no difference existing for condition 3. It can be concluded that the selected loads and the model used interfere in the determination of CP during arm crank exercise, and can modify the time to exhaustion during submaximal exercise performed in relative loads to CP.
Issue Date: 
1-Feb-2000
Citation: 
Revista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 6, n. 1, p. 1-4, 2000.
Time Duration: 
1-4
Publisher: 
Sociedade Brasileira de Medicina do Exercício e do Esporte
Keywords: 
  • Potência crítica
  • Modelo linear
  • Tempo de exaustão
  • Ergômetro de braço
  • Critical power
  • Linear model
  • Time to exhaustion
  • Arm ergometer
Source: 
http://dx.doi.org/10.1590/S1517-86922000000100002
URI: 
http://hdl.handle.net/11449/20688
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/20688
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 