ASSESSMENT of POLYATOMIC INTERFERENCES ELIMINATION USING A COLLISION REACTION INTERFACE (CRI) FOR INORGANIC ANALYSIS of FUEL ETHANOL BY ICP-QMS
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Universidade Federal de São Carlos (UFSCar)
ISSN: 
0003-2719
Sponsorship: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Sponsorship Process Number: 
  • FAPESP: 06/59083-9
  • FAPESP: 10/17387-7
Abstract: 
The effectiveness of a collision-reaction interface (CRI) as instrumental device and the addition of oxygen in the composition of auxiliary gas were evaluated to minimize polyatomic species generated in plasma gas caused by direct introduction of fuel ethanol samples through spray chambers in inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). The oxygen flow-rate was optimized as a compromise among signal counts, signal to background ratio (SBR), and background equivalent concentration (BEC). For 12.5mL min(-1) O-2, ethanol samples diluted 20 times were introduced into the plasma and deposits of carbon compounds on the sampler and/or skimmer cones were not observed. The performance of CRI using H-2 and He inserted through the sampler or skimmer cones was evaluated. Hydrogen gas added through the skimmer cone was more efficient to reduce blank and BEC values. This strategy was necessary to eliminate spectral interferences caused by (Ar12C+)-Ar-40, Ar-40(16) O+, (CO+)-C-12-O-16, C-12(2)+ at isotopes Cr-52(+), Fe-56(+), Si-28(+) and Mg-24(+), respectively. Using matrix-matching calibration and Y internal standard, the optimized method was applied to the determination of Al, Ba, Co, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, Pb, Sb, Si, V, and Zn in fuel ethanol. Accuracy of developed method was checked after addition/recovery tests. Recoveries and RSD (n = 12) for all elements varied within the 78-114% and 0.4-2% ranges, respectively. Limits of detection for all elements obtained by combining CRI and ICP-QMS were always better than 0.80 mu g L-1 except for Si at 14 mu g L-1.
Issue Date: 
1-Jan-2012
Citation: 
Analytical Letters. Philadelphia: Taylor & Francis Inc, v. 45, n. 9, p. 1111-1121, 2012.
Time Duration: 
1111-1121
Publisher: 
Taylor & Francis Inc
Keywords: 
  • Collision-reaction interface
  • Ethanol fuel
  • ICP-QMS
  • Polyatomic interference
Source: 
http://dx.doi.org/10.1080/00032719.2012.670793
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/40595
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.