You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/9624
Title: 
Transferência de oxigênio em reatores de leito fluidizado com circulação em tubos concêntricos em meios bifásico e trifásico com variação da relação entre diâmetros
Other Titles: 
Oxygen transfer in two and three-phase internal-loop airlift reactor with riser diameter variation
Author(s): 
Institution: 
  • Companhia de Saneamento Básico do Estado de São Paulo (SABESP)
  • Universidade Estadual Paulista (UNESP)
ISSN: 
1413-4152
Abstract: 
  • A eficiência do reator de leito fluidizado com circulação em tubos concêntricos depende das condições hidrodinâmicas que influem na transferência de oxigênio ao biofilme. Este trabalho investigou a influência da relação entre diâmetros dos tubos e da concentração de meio suporte (areia), sobre o coeficiente global de transferência de oxigênio (K La). Os ensaios - em reatores de 2,6 m de altura, com diâmetro externo de 250 mm e internos de 100, 125, 150 e 200 mm - empregaram vazões de ar até 2.500 L.h-1 e concentrações de até 150 g.L-1 de areia. O K La aumentou ligeiramente com 30 g.L-1 e diminuiu para concentrações maiores, confirmando relatos da literatura em condições semelhantes. Um modelo para K La em meio bifásico foi ajustado para as diversas relações ensaiadas entre a área externa e a interna, postulando-se uma redução na razão entre a transferência na fase líquida e o diâmetro da bolha com o aumento da vazão de ar.
  • The efficiency of the concentric tubes internal-loop airlift reactor depends on the hydrodynamic conditions that affect oxygen transfer to the biofilm. This work studied the effects of the relation between diameters of the tubes and of the carrier (sand) concentration on the global oxygen transfer coefficient (K La). The tests - in 2,6 m high reactors with 250 mm external diameter and 100, 125, 150 and 200 mm internal diameters - were performed with air flow taxes up to 2,500 L.h-1 and sand concentrations up to 150 g.L-1. The K La increased slightly for 30 g.L-1 and decreased for higher concentrations, in accordance with related data for similar conditions. A model for K La in biphasic medium was fitted embracing all the external/internal area relationships tested, based on the reduction of the liquid phase transfer coefficient and the bubble diameter ratio with increasing air flow rates.
Issue Date: 
1-Sep-2010
Citation: 
Engenharia Sanitaria e Ambiental. ABES, v. 15, n. 3, p. 267-274, 2010.
Time Duration: 
267-274
Publisher: 
ABES
Keywords: 
  • leito fluidizado
  • reator aeróbio
  • transferência de oxigênio
  • fluidized bed
  • aerobic reactor
  • oxygen transfer
Source: 
http://dx.doi.org/10.1590/S1413-41522010000300010
URI: 
http://hdl.handle.net/11449/9624
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/9624
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.