Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/111651
Título: 
Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase
Autor(es): 
Instituição: 
  • Universidade Federal de São Carlos (UFSCar)
  • Universidade Estadual Paulista (UNESP)
  • Universidade Federal de São Paulo (UNIFESP)
ISSN: 
1567-5394
Financiador: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
  • nBioNet network (Brazil)
Resumo: 
An important step in several bioanalytical applications is the immobilization of biomolecules. Accordingly, this procedure must be carefully chosen to preserve their biological structure and fully explore their properties. For this purpose, we combined the versatility of the layer-by-layer (LbL) method for the immobilization of biomolecules with the protective behavior of liposome-encapsulated systems to fabricate a novel amperometric glucose biosensor. To obtain the biosensing unit, an LbL film of the H2O2 catalyst polypeptide microperoxidase-11 (MP-11) was assembled onto an indium-tin oxide (ITO) electrode followed by the deposition of a liposome-encapsulated glucose oxidase (GOx) layer. The biosensor response toward glucose detection showed a sensitivity of 0.91 +/- 0.09 (mu A/cm(2))/mM and a limit of detection (LOD) of 8.6 +/- 1.1 mu M, demonstrating an improved performance compared to similar biosensors with a single phospholipid-liposome or even containing a non-encapsulated GOx layer. Finally, glucose detection was also performed in a zero-lactose milk sample to demonstrate the potential of the biosensor for food analysis. (C) 2014 Elsevier B.V. All rights reserved.
Data de publicação: 
1-Abr-2014
Citação: 
Bioelectrochemistry. Lausanne: Elsevier Science Sa, v. 96, p. 37-42, 2014.
Duração: 
37-42
Publicador: 
Elsevier B.V.
Palavras-chaves: 
  • Glucose biosensor
  • Microperoxidase-11
  • Layer-by-layer technique
  • Liposome
  • Biosensor
Fonte: 
http://dx.doi.org/10.1016/j.bioelechem.2014.01.001
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/111651
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.