You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/112972
Title: 
In Vivo Osteogenesis and In Vitro Streptococcus mutans Adherence: Porous-Surfaced Cylindrical Implants vs Rough-Surfaced Threaded Implants
Author(s): 
Institution: 
  • Air & Space Inst
  • Universidade Estadual Paulista (UNESP)
  • Fac Pindamonhangaba FAPI
ISSN: 
0882-2786
Sponsorship: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Sponsorship Process Number: 
FAPESP: 05/03709-4
Abstract: 
Purpose: To analyze and compare bone apposition at the interface of commercially available rough-surfaced, threaded implants with porous-surfaced, cylindrical implants after several healing periods in a rabbit model. In addition, the study aimed to elucidate the influence of the implant surface configuration on Streptococcus mutans adherence. Materials and Methods: Using a powder metallurgy technique, a new method was developed to produce titanium implants with a dense core and porous surface to increase bone-implant contact (BIC). Sixty implants were placed in 15 rabbits. In each rabbit, two experimental and two control implants were placed in the right or left tibia. The experimental implants were inserted under pressure into the surgical cavity, while the control implants were self-threaded. The rabbits were euthanized at 4, 8, and 12 weeks post-insertion for undecalcified histologic processing and morphometric evaluation of BIC. Additionally, 16 implants, eight experimental and eight control, were incubated with S mutans to evaluate adherence for each type of implant. Analysis of variance with repeated measures and the Student t test were applied, respectively. Results: Histology showed intimate bone-implant interfaces without soft tissue intervention in both groups. Porous-surfaced cylindrical implants showed a higher BIC (72.41% +/- 9.47%) than the rough-surfaced screw implants (61.23% +/- 14.12%) (P = .013), while no significant difference in S mutans adherence occurred (P = .351). The implant type effect was more pronounced in the 4-week healing period groups (P = .029). The percentage of BIC was similar throughout the healing periods (P = .333), but gradually increased over time. Conclusion: Within the limitations of this study, the results suggest that the new implant design increased BIC without provoking greater S mutans adherence.
Issue Date: 
1-Nov-2013
Citation: 
International Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 28, n. 6, p. 1630-1638, 2013.
Time Duration: 
1630-1638
Publisher: 
Quintessence Publishing Co Inc
Keywords: 
  • bacterial adherence
  • bone ingrowth
  • implant design
  • porous titanium
  • surface
Source: 
http://dx.doi.org/10.11607/jomi.2747
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/112972
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.