Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/129089
Título: 
An impedimetric biosensor to test neat serum for dengue diagnosis
Autor(es): 
Instituição: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0925-4005
Financiador: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Número do financiamento: 
FAPESP: 2012-22820-7
Resumo: 
NS1, a non-structural dengue protein, has been used as a biomarker for the detection of viremia in dengue diagnosis. In this work, an impedimetric label-free immunosensor based on an anti-NS1 modified gold electrode was developed. To immobilize anti-NS1, a mixed self-assembled monolayer consisting of 11-mercaptoundecanoic acid (for covalent anti-NS1 attachment) and 6-mercaptohexanol (as a spacer) was prepared. The impedance spectra were recorded in the presence of a redox probe ( [Fe(CN)(6)](3-/4-)) to monitor changes in charge-transfer resistance associated with target binding both in PBS and neat serum. A calibration curve was constructed in order to obtain analytical parameters. NS1 was diluted in PBS to final concentrations in the linear range of 0.01-2.00 mu g mL(-1) with a sensitivity of 14.1 percentage decade(-1) (R similar to 0.99) and a limit of detection (LOD) of 3 ng mL(-1). A linear range 0.01-1.00 mu g mL(-1) of NS1 diluted in neat serum was also obtained (R similar to 0.98) with a sensitivity of 10.4 percentage decade(-1) and a LOD of 30 ng mL(-1). The results open new insights into the potential use of this biosensor for point-of-care and bedside applications for dengue diagnosis.
Data de publicação: 
5-Jul-2015
Citação: 
Sensors And Actuators B-chemical. Lausanne: Elsevier Science Sa, v. 213, p. 150-154, 2015.
Duração: 
150-154
Publicador: 
Elsevier B.V.
Palavras-chaves: 
  • Dengue
  • NS1 protein
  • Electrochemical impedance spectroscopy (EIS)
  • Label-free biosensor
  • Blood serum
Fonte: 
http://www.sciencedirect.com/science/article/pii/S0925400515002427
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/129089
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.