Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/14579
- Title:
- Autoclaved, previously used intravaginal progesterone devices induces estrus and ovulation in anestrous Toggenburg goats
- Universidade Federal de Viçosa (UFV)
- Universidade Federal Fluminense (UFF)
- Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
- Universidade Estadual Paulista (UNESP)
- 0378-4320
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
- Vicosa Federal University
- Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
- Intravaginal progesterone devices are used worldwide for estrus induction in goats. Reused devices are able to induce estrus; however, this can be a health risk within a flock. The objective was to compare new and previously used (and autoclaved) progesterone-releasing intravaginal devices for induction of estrus and ovulation in seasonally anestrous Toggenburg goats. Anestrous goats (n = 42) received new intravaginal devices containing 0.3 g progesterone (CONTROL), or similar devices previously used for either 6 (USED6) or 12d (USED12) and subsequently autoclaved. All goats received 5 mg dinoprost at device insertion and 200 IU eCG 5 d later, and all devices were removed after 6 d. After device removal, estrus was monitored and females displaying signs of estrus were mated by fertile bucks. Transrectal ovarian ultrasonography was performed after device removal until detection of ovulation. Blood samples were collected for determination of plasma progesterone concentration at different times. There was no difference (P > 0.05) among groups CONTROL, USED6 or USED12 for: estrus response (87,100 or 100%, respectively); duration of estrus (32.3 +/- 2.3, 25.2 +/- 3.4 or 27.3 +/- 4.1 h); ovulation rate (100,88 or 100%); number of ovulations (1.5 +/- 0.2, 1.9 +/- 0.3 or 1.7 +/- 0.3); and pregnancy rate (60, 58 or 67%). Plasma progesterone (P4) concentrations were greater (P < 0.05) in CONTROL than in USED6-treated and USED12-treated goats (7.2 +/- 1.2, 4.7 +/- 0.7 and 4.3 +/- 0.6 ng/mL, respectively) at 6h after device insertion; these differences were maintained until 4d after device insertion (3.4 +/- 0.4, 2.3 +/- 0.2, and 2.5 +/- 0.2 ng/mL). Overall, plasma progesterone concentrations were greater (P < 0.05) in nulliparous than in lactating goats (3.1 +/- 0.8 compared to 2.4 +/- 0.6 ng/mL, respectively). In conclusion, autoclaved, previously used intravaginal progesterone-releasing devices resulted in significant lesser plasma progesterone concentrations than new devices, but were similarly effective in inducing estrus and ovulation in anestrous goats. (C) 2011 Elsevier B.V. All rights reserved.
- 1-Nov-2011
- Animal Reproduction Science. Amsterdam: Elsevier B.V., v. 129, n. 1-2, p. 50-55, 2011.
- 50-55
- Elsevier B.V.
- Goats
- CIDR
- Estrus induction
- Ovarian follicular dynamics
- Seasonal anestrus
- http://dx.doi.org/10.1016/j.anireprosci.2011.09.012
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/14579
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.