Influence of Pigment and Opacifier on Dimensional Stability and Detail Reproduction of Maxillofacial Silicone Elastomer
Autor(es): 
Instituição: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1049-2275
Financiador: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Número do financiamento: 
FAPESP: 08/52766-9
Resumo: 
We evaluated the influence of chemical disinfection and accelerated aging on the dimensional stability and detail reproduction of a silicone elastomer containing an opacifier and/or a pigment. A total of 120 samples were fabricated from Silastic MDX 4-4210 silicone and divided into groups (n - 10) according to pigment and/or opacifier (ceramic powder and/or barium sulfate) and disinfectant solution (neutral soap, Efferdent, or 4% chlorhexidine). The specimens were disinfected 3 times per week during 60 days and then subjected to accelerated aging for 1008 hours. Dimensional stability and detail reproduction tests were performed after specimens' fabrication (baseline) and chemical disinfection and periodically during accelerated aging (252, 504, and 1008 hours). The results were analyzed using 3-way repeated-measures analysis of variance and the Tukey Honestly Significant Difference test (a = 0.05). All groups exhibited dimensional changes over time. The disinfectant, pigment, and time (P < 0.0001) affected the dimensional stability of silicone. Statistically significant dimensional differences were not observed between the tested groups. Accelerated aging influenced the dimensional stability of the samples. All groups scored 2 in the detail reproduction tests, which represents the full reproduction of 3 test grooves with accurate angles. Incorporation of opacifier and/or pigment alters the dimensional stability of silicones used in facial prosthetics but seems to have no influence on detail reproduction. Accelerated aging is responsible for most of the dimensional changes in Silastic MDX4 4210, but all dimensional changes measured in this study remained within the limits of stability necessary for this application.
Data de publicação: 
1-Set-2011
Citação: 
Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 22, n. 5, p. 1612-1616, 2011.
Duração: 
1612-1616
Publicador: 
Lippincott Williams & Wilkins
Palavras-chaves: 
  • Maxillofacial prostheses
  • silicone
  • opacifier
  • pigments
Fonte: 
http://dx.doi.org/10.1097/SCS.0b013e31822e5ef2
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/15309
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.