Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/15358
Título: 
Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer
Autor(es): 
Instituição: 
  • Universidade Estadual Paulista (UNESP)
  • Universidade Estadual de Campinas (UNICAMP)
ISSN: 
1475-925X
Financiador: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Número do financiamento: 
FAPESP: 08/52766-9
Resumo: 
Background: We evaluated the influence of chemical disinfection and accelerated aging on the dimensional stability and detail reproduction of a silicone elastomer containing one of two opacifiers.Methods: A total of 90 samples were fabricated from Silastic MDX 4-4210 silicone and divided into groups (n = 10) according to opacifier content (barium sulfate or titanium dioxide) and disinfectant solution (neutral soap, Efferdent, or 4% chlorhexidine). The specimens were disinfected 3 times per week during 60 days and then subjected to accelerated aging for 1008 hours. Dimensional stability and detail reproduction tests were performed after specimens' fabrication (baseline), chemical disinfection and periodically during accelerated aging (252, 504, and 1008 hours). The results were analyzed using 3-way repeated-measures ANOVA and the Tukey HSD test (alpha = 0.05).Results: All groups exhibited dimensional changes over time. The opacifier (p = .314), period (p < .0001) and their interactions (p = .0041) affected the dimensional stability of the silicone. Statistical significant dimensional differences occurred between groups with (0.071) and without opacifiers (0.053). Accelerated aging influenced the dimensional stability of the samples. All groups scored 2 in the detail reproduction tests, which represents the fully reproducing of three test grooves with accurate angles.Conclusions: Incorporation of opacifiers alters the dimensional stability of silicones used in facial prosthetics, but seems to have no influence on detail reproduction. Accelerated aging is responsible for most of the dimensional changes in Silastic MDX4 4210, but all dimensional changes measured in this study remained within the limits of stability necessary for this application.
Data de publicação: 
16-Dez-2010
Citação: 
Biomedical Engineering Online. London: Biomed Central Ltd., v. 9, p. 9, 2010.
Duração: 
9
Publicador: 
Biomed Central Ltd.
Fonte: 
http://dx.doi.org/10.1186/1475-925X-9-85
Endereço permanente: 
http://hdl.handle.net/11449/15358
Direitos de acesso: 
Acesso aberto
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/15358
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.