Effect of microwave disinfection on the surface roughness of three denture base resins after tooth brushing
Autor(es): 
Instituição: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0734-0664
Financiador: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Número do financiamento: 
FAPESP: 04/03821-6
Resumo: 
Objective: This study investigated the effect of microwave disinfection on the roughness of three heat-polymerised acrylic resins after tooth brushing. Background: Microwave disinfection has been recommended to reduce cross-contamination. However, this procedure may also influence the physical and mechanical properties of acrylic resins. Materials and methods: Specimens (40 x 20 x 2 mm) of resins: Lucitone 550 (L), QC 20(QC) and Acron MC (A) were prepared and divided into four groups (n = 10): Control groups 1 (C1) and 2 (C2) stored in water for 48 h or 7 days; Test groups 1 (MW2) and 2 (MW7) stored in water for 48 h and disinfected (650 W for 6 min) daily for 2 or 7 days, respectively. After treatments, the specimens were placed in a tooth brushing machine at a rate of 60 reciprocal strokes per minute. The specimens were brushed with 20 000 strokes, which represent approximately 2 years of denture cleansing. The surface roughness (Ra) was evaluated before and after the tooth brushing. Data were analysed by two-way anova and Tukey Honestly Significant Difference (HSD) post hoc tests (alpha = 0.05). Results: The data revealed significant changes between test groups for A and L resins. Comparison among resins revealed that for MW7, the roughness of A was significantly lower than that of L. After the seven microwave cycles, it could be seen that the roughness values of QC were significantly lower than those of L. Conclusions: The roughness of QC after brushing was not significantly affected by microwave disinfection. For A and L, seven microwave cycles resulted in increased roughness.
Data de publicação: 
1-Dez-2011
Citação: 
Gerodontology. Malden: Wiley-blackwell, v. 28, n. 4, p. 277-282, 2011.
Duração: 
277-282
Publicador: 
Wiley-Blackwell
Palavras-chaves: 
  • acrylic resins
  • tooth brushing
  • abrasion
  • microwave disinfection
Fonte: 
http://dx.doi.org/10.1111/j.1741-2358.2010.00393.x
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/16527
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.