Development of an AMR-ACB Array for Gastrointestinal Motility Studies
Autor(es): 
Instituição: 
  • Universidade Estadual Paulista (UNESP)
  • Univ Estadual Ciencias Saúde Alagoas
  • Univ Fed Mato Grosso
  • Universidade de São Paulo (USP)
ISSN: 
0018-9294
Financiador: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo: 
The association between anisotropic magnetoresistive (AMR) sensor and AC biosusceptometry (ACB) to evaluate gastrointestinal motility is presented. The AMR-ACB system was successfully characterized in a bench-top study, and in vivo results were compared with those obtained by means of simultaneous manometry. Both AMR-ACB and manometry techniques presented high temporal cross correlation between the two periodicals signals (R = 0.9 +/- 0.1; P < 0.05). The contraction frequencies using AMR-ACB were 73.9 +/- 7.6 mHz and using manometry were 73.8 +/- 7.9 mHz during the baseline (r = 98, p < 0.05). The amplitude of contraction using AMR-ACB was 396 +/- 108 mu T.s and using manometry were 540 +/- 198 mmHg.s during the baseline. The amplitudes of signals for AMR-ACB and manometric recordings were similarly increased to 86.4% and 89.3% by neostigmine, and also decreased to 27.2% and 21.4% by hyoscine butylbromide in all animals, respectively. The AMR-ACB array is nonexpensive, portable, and has high-spatiotemporal resolution to provide helpful information about gastrointestinal tract.
Data de publicação: 
1-Out-2012
Citação: 
IEEE Transactions on Biomedical Engineering. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 59, n. 10, p. 2737-2743, 2012.
Duração: 
2737-2743
Publicador: 
Institute of Electrical and Electronics Engineers (IEEE)
Palavras-chaves: 
  • Biomagnetics
  • biomedical equipment
  • biosusceptometry
  • gastroenterology
  • magnetoresistive device
Fonte: 
http://dx.doi.org/10.1109/TBME.2012.2208748
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/17690
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.