Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/20094
- Título:
- Avaliação em escala laboratorial da utilização do processo eletrolítico no tratamento de águas
- Laboratory scale assessment of an electrolytic process for water treatment
- Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
- Serviço Autônomo de Água e Esgoto (SAAE)
- Universidade Estadual Paulista (UNESP)
- 0100-4042
- Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.
- 1-Jan-2008
- Química Nova. Sociedade Brasileira de Química, v. 31, n. 3, p. 508-513, 2008.
- 508-513
- Sociedade Brasileira de Química
- electrolytic treatment
- water disinfection
- water quality
- http://dx.doi.org/10.1590/S0100-40422008000300008
- http://hdl.handle.net/11449/20094
- Acesso aberto
- outro
- http://repositorio.unesp.br/handle/11449/20094
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.