You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27577
Title: 
Extração por fluido supercrítico de alguns inseticidas carbamatos em amostras de batata, com determinação por HPLC/fluorescência e confirmação por HPLC/espectrometria de massas
Other Titles: 
Supercritical fluid extraction for some carbamate insecticides in potatoes samples, with HPLC/fluorescence determination and HPLC/mass spectrometry confirmation
Author(s): 
Institution: 
  • Universidade Federal do Maranhão (UFMA)
  • CSIC Centro de Investigación y Desarrollo Departamento Química Ambiental
  • Universidade Federal de Viçosa (UFV)
  • Universidade Estadual Paulista (UNESP)
ISSN: 
0100-4042
Sponsorship: 
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Abstract: 
Six supercritical fluid extraction (SFE) methods were tested, by varying the following operational parameters: CO2 pressure, time and temperature of extraction, type and proportion of static modifier, and Hydromatrix®/sample rate into cell. Firstly, insecticide carbamates were extracted from spiked potatoes samples (fortification level of 0,5 mg.Kg-1) by using SPE procedures, and then final extracts were analyzed HPLC/fluorescence. Good performance was observed with SFE methods that operated with values of temperature and CO2 pressure of 50 ºC and 350 bar, respectively. Best efficiency was obtained when it was used acetonitrile as a modifier (3% on the cell volume), and Hydromatrix®/sample rate of 2:1. Static time was of 1 min; total extraction time was of 35 min; dynamic extraction was performed with 15 mL of CO2, and it was used methanol (2 mL) for the dissolution of the final residue. In such conditions, pesticide recoveries varied from 72 to 94%, depending on the analyzed compound. In higher extraction temperatures, a rapid degradation was observed for some compounds, such as aldicarb and carbaryl; presence of their metabolites was further confirmed by HPLC-APCI/MS in positive mode. Detection limits for chromatographic analysis varied from 0,2 to 1,3 ng.
Issue Date: 
1-May-2002
Citation: 
Química Nova. Sociedade Brasileira de Química, v. 25, n. 2, p. 214-220, 2002.
Time Duration: 
214-220
Publisher: 
Sociedade Brasileira de Química
Keywords: 
  • SFE method
  • HPLC/FS
  • HPLC-APCI/MS
  • potatoes
  • pesticides
  • carbamate insecticides
Source: 
http://dx.doi.org/10.1590/S0100-40422002000200008
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/27577
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.