You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/28981
Title: 
Sutura arterial com técnicas contínua e de pontos separados, utilizando-se os fios polipropilene e polidioxanone: estudo experimental em coelhos
Other Titles: 
Arterial suture with continuous and interrupted techniques, using polypropylene and polydioxanone threads: experimental study in rabbits
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0102-8650
Abstract: 
  • OBJETIVO: Observar o comportamento da sutura arterial em aortas abdominais de coelhos em crescimento, comparando-se as técnicas contínua e com pontos separados, empregando-se dois tipos de fios: Polipropilene 7-0 (inabsorvível) e Polidioxanone 7-0 (absorvível). MÉTODOS: Grupos: GI - Controle (sem sutura); GII - Polipropilene, Pontos Separados; GIII - Polipropilene, Contínua; GIV - Polidioxanone, Pontos Separados e GV - Polidioxanone, Contínua. Cada grupo foi subdividido em quatro Momentos de Eutanásia: aos 7, 14, 30 e 60 dias de pós-operatório. Foram avaliados: peso dos animais, diâmetros e pulsos arteriais, estenose, trombose, aderências, aortografia, visibilidade do fio, cicatrização e microscopia. RESULTADOS: a) após 60 dias, o local da linha de sutura cresceu de forma significativa em todos os grupos; b) a técnica de sutura com pontos separados causou menor estenose da linha de sutura, observada tanto no ato cirúrgico, como na eutanásia dos animais; c) no exame histopatológico, as diferenças encontradas entre grupos foram transitórias, não persistindo após 60 dias de pós-operatório. CONCLUSÃO: O polidioxanone mostrou ser a melhor opção, entre os dois fios, para sutura de artérias em crescimento, pois causa pouca ou nenhuma restrição ao crescimento arterial na linha de sutura, mesmo quando se emprega a técnica contínua.
  • PURPOSE: To assess the arterial suture, comparing continuous and interrupted techniques, in abdominal aorta of growing rabbbits, using two types of suture material: Polypropylene 7-0 (nonabsorbable) and Polydioxanone 7-0 (absorbable). METHODS: Groups: GI - Control, without arterial suture; GII - Polypropylene, Interrupted technique; GIII - Polipropilene, Continuous technique; GIV - Polydioxanone, Interrupted technique and GV - Polydioxanone, Continuous technique. Each group was subdivided in four Moments of Euthanasia , according with the number of days after surgery: 7 , 14 , 30 and 60 days. The following itens were assessed: weight, arterial diameters and pulse, stenosis, thrombosis, tissue adherence at the suture line, aortography, suture material visibility, suture line healling visibility and microscopic study. RESULTS: a) after 60 days, the suture line site had a significant growing in all groups; b) interrupted technique result less suture line stenosis in surgical act and in euthanasia c) the difference between groups showed in the microscopic study, was transitory, not pesisting after 60 days post surgery; CONCLUSION: Polydioxanone is better than polypropylene for suture in growing artery, not causing (or causing little) restriction to the growing of the suture line, even though using continuous technique.
Issue Date: 
1-Oct-2003
Citation: 
Acta Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 18, n. 5, p. 431-437, 2003.
Time Duration: 
431-437
Publisher: 
Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
Keywords: 
  • Artéria
  • Sutura
  • Polipropilene
  • Polidioxanone
  • Artery
  • Suture
  • Polypropylene
  • Polydioxanone
Source: 
http://dx.doi.org/10.1590/S0102-86502003000500008
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/28981
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.