Effect of microwave disinfection on physical and mechanical properties of acrylic resins
Author(s): 
Institution: 
  • Universidade Estadual de Campinas (UNICAMP)
  • Itaúna University
  • Universidade Estadual Paulista (UNESP)
ISSN: 
  • 0103-6440
  • 1806-4760
Abstract: 
This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.
Issue Date: 
1-Dec-2008
Citation: 
Brazilian Dental Journal, v. 19, n. 4, p. 348-353, 2008.
Time Duration: 
348-353
Keywords: 
  • Acrylic resin
  • Flexural strength
  • Hardness
  • Impact
  • Microwave disinfection
  • acrylic acid resin
  • dental care
  • disinfection
  • equipment
  • hardness
  • materials testing
  • methodology
  • microwave radiation
  • pliability
  • radiation exposure
  • Acrylic Resins
  • Dental Stress Analysis
  • Disinfection
  • Equipment Contamination
  • Materials Testing
  • Microwaves
  • Pliability
Source: 
http://dx.doi.org/10.1590/S0103-64402008000400011
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/70713
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.