Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/72662
Título: 
GEANT4 tuning for pCT development
Autor(es): 
Instituição: 
  • Universidade do Estado do Rio de Janeiro (UERJ)
  • Universidade Tecnológica Federal Do Paraná
  • Centro de Aplicaciones Tecnologicas Y Desarrollo Nuclear
  • Universidade Estadual Paulista (UNESP)
  • Universidade Federal do Rio de Janeiro (UFRJ)
ISSN: 
  • 0094-243X
  • 1551-7616
Resumo: 
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. Moreover, the spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through aluminum absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadrontherapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development. © 2011 American Institute of Physics.
Data de publicação: 
9-Set-2011
Citação: 
AIP Conference Proceedings, v. 1351, p. 340-344.
Duração: 
340-344
Palavras-chaves: 
  • GEANT4 code
  • Monte Carlo simulations
  • Proton computed tomography (pCT)
Fonte: 
http://dx.doi.org/10.1063/1.3608985
Endereço permanente: 
Direitos de acesso: 
Acesso restrito
Tipo: 
outro
Fonte completa:
http://repositorio.unesp.br/handle/11449/72662
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.