Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/8970
- Title:
- Effect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis
- Universidade de São Paulo (USP)
- Universidade Estadual Paulista (UNESP)
- Universidade Federal de Santa Maria (UFSM)
- 0905-7161
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
- Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
- FAPESP: 99/01402-6
- FAPESP: 05/56182-3
- In cantilevered implant-supported complete prosthesis, the abutments' different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis.A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges.Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase.Abutment's height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis.To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.
- 1-Feb-2009
- Clinical Oral Implants Research. Malden: Wiley-blackwell Publishing, Inc, v. 20, n. 2, p. 196-200, 2009.
- 196-200
- Wiley-Blackwell Publishing, Inc
- biomechanics
- dental implants
- mechanical stress
- strain gauges
- http://dx.doi.org/10.1111/j.1600-0501.2008.01609.x
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/8970
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.