Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/9795
- Title:
- Sizing PZT Transducers in Impedance-Based Structural Health Monitoring
- Minist Educ Brazil
- Universidade Estadual Paulista (UNESP)
- Virginia Polytech Inst & State Univ
- 1530-437X
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
- Ministry of Education of Brazil
- AFOSR MURI
- Ministry of Education of Brazil: BEX 0125/10-5
- Ministry of Education of Brazil: BEX 3634/09-4
- AFOSR MURI: FA9559-060-0309
- A theoretical and experimental analysis regarding the correct size of PZT (Lead Zirconate Titanate) transducers used in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique is presented. Tests were carried out on aluminum structures using 5A and 5H PZT patches of various sizes. The results show that the sensitivity of SHM systems for damage detection can be optimized if the transducers are correctly sized according to the proposed procedure.
- 1-Jun-2011
- IEEE Sensors Journal. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 11, n. 6, p. 1405-1414, 2011.
- 1405-1414
- Institute of Electrical and Electronics Engineers (IEEE)
- Electromechanical impedance
- PZT ceramics
- structural engineering
- structural health monitoring (SHM)
- http://dx.doi.org/10.1109/JSEN.2010.2098865
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/9795
There are no files associated with this item.