Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/101059
- Title:
- Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno: análise histológica e histométrica em tíbias de coelhos
- Salim, Martha Alayde Alcantara
- Universidade Estadual Paulista (UNESP)
- Este estudo teve como objetivo avaliar o reparo ósseo em defeitos periimplatares experimentais utilizando enxerto autógeno e implante de matriz óssea bovina desmineralizada em tíbias de coelhos. Foram instalados 30 implantes de titânio diâmetro de 3,75 mm plataforma regular (4,1 mm) e altura de 10 mm, no qual cada animal recebeu dois implantes na face lateral da porção mediana da tíbia. Ao redor dos implantes foi confeccionado defeito ósseo de 6,0 mm de diâmetro através da trefina e enxertado no local osso autógeno ou matriz óssea heterógena desmineralizada. As lâminas obtidas foram submetidas à análise histológica e histométrica com contagem das áreas de osso neoformado, matriz óssea bovina, medula e enxerto de osso autógeno. Como resultado observou-se diferença significativa entre a formação de novo osso no período de 15 dias quando comparado o grupo de implante de matriz óssea bovina desmineralizada e enxerto autógeno, demonstrando maior formação óssea neste último; e diferença significativa entre a permanência do tecido implantado em relação ao enxerto autógeno, demonstrado pela permanência da matriz no período de 60 dias. Avaliando os dados obtidos nesta pesquisa concluímos que o processo de reparo periimplantar ocorreu com maior neoformação óssea no grupo tratado por enxerto de osso autógeno e a matriz óssea bovina desmineralizada se comportou como um condutor ósseo de lenta absorção sem demonstrar reação inflamatória aguda ou crônica.
- This study aimed to evaluate the bone healing in experimental periimplatar defects using autogenous graft and implantation of bovine demineralized bone matrix in the tibia of rabbits. Were installed 30 titanium implants of 3.75 mm diameter regular platform (4.1 mm) and height of 10 mm, in which each animal received two implants in the median portion of the tibial. Around the implants was made bone defect of 6.0 mm in diameter through the trephine and grafted in place autogenous bone or demineralized bone matrix heterogenous. The slides obtained were subjected to histological and histometric count with areas of newly formed bone, bovine bone matrix, bone marrow and bone graft. Results revealed a significant difference between the formation of new bone within 15 days when compared to the group of implant bovine demineralized bone matrix and autogenous graft, showing a higher bone formation in the latter, and a significant difference between the permanence of the implanted tissue in compared to autograft, demonstrated by the permanence of the matrix within 60 days. Evaluating the data obtained in this study concluded that the repair process was better in periimplant bone formation than in the group treated with autogenous bone graft and demineralized bovine bone matrix acted as a conductor low absorption without showing acute inflammatory reaction or chronic.
- 27-Nov-2009
- SALIM, Martha Alayde Alcantara. Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno: análise histológica e histométrica em tíbias de coelhos. 2009. 114 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araçatuba, 2009.
- 114 f. : il. + 1 CD-ROM
- Universidade Estadual Paulista (UNESP)
- Implantes dentarios endoosseos
- Ossos - Enxerto
- Implante dentário endoósseo
- Transplante ósseo
- Matriz óssea
- Dental Implantation, Endosseous
- Bone transplantation
- Bone matrix
- Acesso aberto
- outro
- http://repositorio.unesp.br/handle/11449/101059
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.