You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/11118
Title: 
Extraocular muscle fixation to porous polyethylene orbital implants using 2-octyl-cyanoacrylate
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • University of Adelaide
ISSN: 
1120-6721
Sponsorship: 
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Abstract: 
PURPOSE. To evaluate the efficacy of bioadhesive in attaching the extraocular muscles to porous polyethylene spheres in rabbit enucleated cavities.METHODS. A prospective, experimental study was performed. Eight adult New Zealand white rabbits underwent right enucleation with insertion of an unwrapped 12 mm porous polyethylene sphere. The superior and inferior rectus muscles were attached to the implant with 2-octyl cyanoacrylate placed to the underside of the muscles and application of pressure for 5 seconds. Ninety days after surgery, the orbits were exenterated and four animals underwent histologic evaluation and the other four animals tensile strength testing of the muscle-sphere attachment.RESULTS. There were no exposures or infections of the implants and the muscles remained attached in all cases. Histologic examination showed fibrous tissue reaction at the muscle-sphere attachment with minimal inflammation of the surrounding tissues; a pseudocapsule formation around the spheres and full vascularization of the implant was also observed. There was no evidence of residual glue on histologic examination. Tensile strength testing showed that rupture force was similar between bonded muscle and the porous polyethylene sphere.CONCLUSIONS. The 2-octyl-cyanoacrylate did not cause deleterious effects in orbital tissues and provided strong adhesion between muscles and spheres. Bioadhesive may be an option for attaching the extraocular muscles to orbital implants in anophthalmic cavity reconstruction. (Eur J Ophthalmol 2009; 19: 527-9)
Issue Date: 
1-Jul-2009
Citation: 
European Journal of Ophthalmology. Milan: Wichtig Editore, v. 19, n. 4, p. 527-529, 2009.
Time Duration: 
527-529
Publisher: 
Wichtig Editore
Keywords: 
  • 2-Octyl cyanoacrylate
  • Histology
  • Porous polyethylene sphere
  • Tensile strength testing
Source: 
http://link.periodicos.capes.gov.br/sfxlcl41?&url_ver=Z39.88-2004&url_ctx_fmt=info:ofi/fmt:kev:mtx:ctx&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Extraocular%20muscle%20fixation%20to%20porous%20polyethylene%20orbital%20implants%20using%202-octyl-cyanoacrylate&rft.aufirst=Lucieni%20Cristina&rft.aulast=Barbarini%20Ferraz&rft.date=2009&rft.epage=529&rft.genre=article&rft.issn=1120-6721&rft.issue=4&rft.jtitle=EUROPEAN%20JOURNAL%20OF%20OPHTHALMOLOGY&rft.pages=527-529&rft.spage=527&rft.stitle=EUR%20J%20OPHTHALMOL&rft.volume=19&rfr_id=info:sid/www.isinet.com:WoK:UA&rft.au=Schellini%2C%20Silvana%20A%2E&rft.au=Wludarski%2C%20Sheila%20L%2E&rft.au=Padovani%2C%20Carlos%20R%2E&rft.au=Selva%2C%20Dinesh
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/11118
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.