Abstract: 
This study evaluated the stress distribution in mandibular full-arch implant-supported fixed dentures with different veneering and metallic infrastructure materials, using three-dimensional finite element analysis. Ten models were obtained from an edentulous human mandible with a complete denture fixed by four implants. Acrylic resin (RES) and porcelain (POR) teeth were associated with infrastructures of titanium (Ti), gold (Au), silver-palladium (AgPd), chrome-cobalt (CoCr) and nickel-chrome (NiCr). A 100-N oblique was applied. The von Mises (sigma vM) and maximum (sigma max) and minimum (sigma min) principal stresses were obtained. The RES-AgPd group showed the lowest sigma vM values, while the RES-Ni-Cr group showed the highest. In the bone tissue, the RES-Au group was the only one that showed different sigma max values with a 12% increase in comparison to the other groups which had similar stress values. In the implants, the groups with Ti, Au and AgPd infrastructures, either with porcelain or resin teeth, showed sigma vM values similar and lower in comparison to the groups with CoCr and NiCr infrastructures. The tooth veneering material influenced the stress values in metallic infrastructures, in which the acrylic resin had the highest values. The veneering and infrastructure materials have influence on stress values of implant-supported dentures, except for the peri-implant bone tissue. (C) 2013 Elsevier B.V. All rights reserved.
Issue Date: 
1-Feb-2014
Citation: 
Materials Science & Engineering C-materials For Biological Applications. Amsterdam: Elsevier Science Bv, v. 35, p. 92-99, 2014.
Time Duration: 
92-99
Publisher: 
Elsevier B.V.
Keywords: 
  • Finite element analysis
  • Implant-supported fixed dentures
  • Infrastructure
Source: 
http://dx.doi.org/10.1016/j.msec.2013.10.022
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/112445
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.