You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/113170
Title: 
Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Univ Ulm
  • Universidade Estadual de Campinas (UNICAMP)
ISSN: 
2045-2322
Sponsorship: 
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • U.S. Department of Energy by Lawrence Livermore National Laboratory (LLNL)
  • LLNL sub-contract
Sponsorship Process Number: 
  • FAPESP: 12/05573-6
  • LLNL sub-contractB598643
  • LLNL sub-contractB603018
Abstract: 
Ozone is a strong oxidant that is globally used as disinfection agent for many purposes including indoor building air cleaning, during food preparation procedures, and for control and killing of bacteria such as E. coli and S. aureus. However, it has been shown that effective ozone concentrations for controlling e. g., microbial growth need to be higher than 5 ppm, thereby exceeding the recommended U. S. EPA threshold more than 10 times. Consequently, real-time monitoring of such ozone concentration levels is essential. Here, we describe the first online gas sensing system combining a compact Fourier transform infrared (FTIR) spectrometer with a new generation of gas cells, a so-called substrate-integrated hollow waveguide (iHWG). The sensor was calibrated using anUVlamp for the controlled generation of ozone in synthetic air. Acalibration function was established in the concentration range of 0.3-5.4 mmolm23 enabling a calculated limit of detection (LOD) at 0.14 mmol m23 (3.5 ppm) of ozone. Given the adaptability of the developed IR sensing device toward a series of relevant air pollutants, and considering the potential for miniaturization e.g., in combination with tunable quantum cascade lasers in lieu of the FTIR spectrometer, a wide range of sensing and monitoring applications of beyond ozone analysis are anticipated.
Issue Date: 
11-Nov-2013
Citation: 
Scientific Reports. London: Nature Publishing Group, v. 3, 5 p., 2013.
Time Duration: 
5
Publisher: 
Nature Publishing Group
Source: 
http://dx.doi.org/10.1038/srep03174
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/113170
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.