Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/125887
- Title:
- Evaluation of the physicochemical properties and push-out bond strength of mta-based root canal cement
- Universidade Estadual Paulista (UNESP)
- Universidade de São Paulo (USP)
- Universidade Federal do Rio Grande do Sul (UFRGS)
- 0974-0333
- Aim: This study investigated the flowability, setting time, pH, calcium release and bond strength of a MTA-based cement (MTA Fillapex®) compared to AH Plus and Sealapex. Materials and methods: For the flowability test, the ISO 6876:2001 specification was utilized and for the setting time test, the ASTM C266-03 specification was utilized. For the pH and calcium release measurements, 10 samples were prepared for each group and analyzed for several different periods. For the push-out test, dentin disks were distributed into three groups, according to the cement utilized and into three subgroups, according to the root third (n = 10). After obturation, the specimens underwent push-out testing. The data were compared statistically using a significance level of 5%. Results: The flowability of all materials was found to be similar (p > 0.05). The setting times were different among the groups tested (MTA Fillapex < Sealapex < AH Plus) (p < 0.05). At days 7 and 28, the MTA Fillapex presented the higher pH values (p < 0.05). At 24 hours and at 14 days, the calcium release of the MTA Fillapex was similar to that of Sealapex (p > 0.05). AH Plus presented the lowest pH and calcium release values (p < 0.05). In all root thirds, the adhesion to the dentin of the MTA Fillapex and Sealapex were significantly lower than that of AH Plus (p < 0.05). Conclusion: MTA Fillapex and Sealapex presented several similar properties and both were found to be different than AH Plus. Clinical significance: This study evaluated the physicochemical and mechanical properties of new MTA-based root canal cement, in order to use this scaler in root canal fillings. MTA Fillapex showed satisfactory properties for clinical use.
- 2013
- The Journal of contemporary Dental Practice, v. 14, n. 6, p. 1094-1099, 2013.
- 1094-1099
- Adhesion
- Calcium
- MTA
- pH
- Push-out
- http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5833&AID=24&num=18
- Acesso aberto
- outro
- http://repositorio.unesp.br/handle/11449/125887
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.