You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/128552
Title: 
Validation of cone-beam computed tomography and magnetic resonance imaging of the porcine spine: a comparative study with multidetector computed tomography and anatomical specimens
Author(s): 
Institution: 
  • Universidade de São Paulo (USP)
  • Instituto do Câncer de São Paulo
  • Universidade Estadual Paulista (UNESP)
ISSN: 
1529-9430
Sponsorship: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Sponsorship Process Number: 
  • FAPESP: 2011/51222-8
  • FAPESP: 2012/00398-1
Abstract: 
BACKGROUND CONTEXT: New spinal interventions or implants have been tested on ex vivo or in vivo porcine spines, as they are readily available and have been accepted as a comparable model to human cadaver spines. Imaging-guided interventional procedures of the spine are mostly based on fluoroscopy or, still, on multidetector computed tomography (MDCT). Cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) are also available methods to guide interventional procedures. Although some MDCT data from porcine spines are available in the literature, validation of the measurements on CBCT and MRI is lacking.PURPOSE: To describe and compare the anatomical measurements accomplished with MDCT, CBCT, and MRI of lumbar porcine spines to determine if CBCT and MRI are also useful methods for experimental studies.STUDY DESIGN: An experimental descriptive-comparative study.METHODS: Sixteen anatomical measurements of an individual vertebra from six lumbar porcine spines (n=36 vertebrae) were compared with their MDCT, CBCT, and MRI equivalents. Comparisons were made for the absolute values of the parameters. RESULTS: Similarities were found in all imaging methods. Significant correlation (p<.05) was observed with all variables except those that included cartilaginous tissue from the end plates when the anatomical study was compared with the imaging methods.CONCLUSIONS: The CBCT and MRI provided imaging measurements of the lumbar porcine spines that were similar to the anatomical and MDCT data, and they can be useful for specific experimental research studies.
Issue Date: 
1-May-2015
Citation: 
Spine Journal. New York: Elsevier Science Inc, v. 15, n. 5, p. 992-999, 2015.
Time Duration: 
992-999
Publisher: 
Elsevier B.V.
Keywords: 
  • Anatomy
  • Porcine
  • Lumbar spine
  • Cone-beam computed tomography
  • Multidetector computed tomography
  • Magnetic resonance imaging
Source: 
http://www.sciencedirect.com/science/article/pii/S1529943015000339
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/128552
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.