Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/130405
- Title:
- Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper Universal system: Histological analysis
- Universidade Estadual Paulista (UNESP)
- Universidade Federal do Amazonas (UFAM)
- Universidade de São Paulo (USP)
- 0972-0707
- The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Materials and Methods: Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Results: Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. Conclusions: The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.
- 2013
- Journal of Conservative Dentistry, v. 16, n. 1, p. 79-82, 2013.
- 79-82
- Cleaning capacity
- Endodontics
- Manual instrumentation
- Rotatory instrumentation
- http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3548353/
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/130405
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.