- Determination of salicylate in blood serum using an amperometric biosensor based on salicylate hydroxylase immobilized in a polypyrrole-glutaraldehyde matrix
- Universidade Estadual de Campinas (UNICAMP)
- Universidade São Francisco (USF)
- Universidade Estadual Paulista (UNESP)
- 0039-9140
- The use of an amperometric biosensor for the salicylate determination in blood serum is described. The biosensor is based on salicylate hydroxylase (EC 1.14.13.1) electropolymerized onto a glassy carbon-working electrode with polypyrrole and glutaraldehyde, to improve the biosensor lifetime. The hexacyanoferrate (II) was also incorporated to work as a redox mediator to minimize possible interferences. The salicylate is enzymatically converted to catechol, which is monitored amperometrically by its electrooxidation at +0.170 V versus SCE (saturated calomel electrode). Salicylate determination was carried out maintaining the ratio between β-NADH and salicylate at 4:1 (30°C). The amperometric response of the biosensor was linearly proportional to the salicylate concentration between 2.3 x 10-6 and 1.4 x 10-5 mol l- 1, in 0.1 mol l-1 phosphate buffer (pH 7.8), containing 0.1 mol l-1 KCl and 5.0 x 10-4 mol l-1 Na2H2EDTA, as supporting electrolyte. The recovery studies, in the presence of several interfering compounds, showed recoveries between 96.4 and 104.8%. The useful lifetime of the biosensor in the concentration range evaluated was at least 40 days, in continuous use. Blood serum samples analyzed by this biosensor showed a good correlation compared to the spectrophotometric method (Trinder) used as reference, presenting relative deviations lower than 7.0%. (C) 2000 Elsevier Science B.V.
- 6-Mar-2000
- Talanta. Amsterdam: Elsevier B.V., v. 51, n. 3, p. 547-557, 2000.
- 547-557
- Elsevier B.V.
- Polypyrrole
- Salicylate determination
- Salicylate hydroxylase
- Serum samples
- Buffer
- Carbon
- Catechol
- Electrolyte
- Ferrocyanide
- Glutaraldehyde
- Mercurous chloride
- Oxygenase
- Phosphate
- Polypyrrole
- Reduced nicotinamide adenine dinucleotide
- Salicylic acid
- Amperometry
- Biosensor
- Blood analysis
- Chemical composition
- Controlled study
- Drug determination
- Electrode
- Intermethod comparison
- Oxidation
- pH
- Polymerization
- Serum
- Spectrophotometry
- Temperature
- http://dx.doi.org/10.1016/S0039-9140(99)00311-2
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/130628
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.