You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/131499
Title: 
Mechanical nociceptive thresholds using four probe configurations in horses
Author(s): 
Institution: 
  • Topcat Metrology Ltd
  • Universidade Estadual Paulista (UNESP)
ISSN: 
1467-2995
Sponsorship: 
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Sponsorship Process Number: 
FAPESP: 2010/08967-0
Abstract: 
To examine the relationship between probe tip size and force readings of mechanical nociceptive thresholds (MTs) to identify appropriate probes for horses. Randomized, crossover study. Eight adult, mixed-breed horses aged 5-10 years, weighing 268-460 kg. Four probe configurations (PCs) were used in random sequence: 1.0 mm diameter (SHARP); 3.2 mm (BLUNT); spring-mounted 1.0 mm (SPRING), and 3 × 2.5 mm (3PIN). A remote-controlled unit on the horse increased force (1.2 N second(-1) ) in a pneumatic actuator on the metacarpus. Mean MT for each PC was calculated from 10 readings for each horse. Data were log-transformed for analysis using mixed-effects anova/linear regression (p < 0.05). Variability of data for each PC was assessed using the coefficient of variation (CV). Mean ± standard deviation MTs were: SHARP, 5.6 ± 2.3 N; BLUNT, 11.4 ± 3.4 N; 3PIN, 9.6 ± 4.6 N, and SPRING 6.4 ± 1.8 N. Mean MT for SHARP was significantly lower than for BLUNT (p < 0.001) and 3PIN (p < 0.001), but not different from SPRING (p > 0.05). Mean MT was significantly higher for BLUNT than for 3PIN (p < 0.05) and SPRING (p < 0.001). Mean MT for 3PIN was significantly higher than for SPRING (p < 0.001). Larger contact area PCs produced higher MTs than smaller PCs, but the relationship was not linear. BLUNT (area: 10-fold greater) gave a MT two-fold higher than SHARP. 3PIN (area: 20-fold greater) produced more variable MTs, less than two-fold higher than SHARP. SPRING was similar to SHARP. CVs were: SHARP, 22.9%; BLUNT, 72.3%; 3PIN, 44.2%, and SPRING, 28.7%. The PC has nonlinear effects on MT. Therefore, it is important to define PC when measuring MT. Smaller probe tips may be preferable as MT data are less variable.
Issue Date: 
21-May-2015
Citation: 
Veterinary Anaesthesia And Analgesia, p. 1-10, 2015.
Time Duration: 
1-10
Publisher: 
Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia
Keywords: 
  • Force
  • Nociception
  • Pain
  • Pressure
  • Probe size
  • Stimulus intensity
Source: 
http://dx.doi.org/10.1111/vaa.12274
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/131499
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.