You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/13436
Title: 
Intravaginal electrical stimulation: a randomized, double-blind study on the treatment of mixed urinary incontinence
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0001-6349
Abstract: 
Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.
Issue Date: 
1-Jan-2006
Citation: 
Acta Obstetricia Et Gynecologica Scandinavica. Oslo: Taylor & Francis As, v. 85, n. 5, p. 619-622, 2006.
Time Duration: 
619-622
Publisher: 
Taylor & Francis As
Keywords: 
  • electrical stimulation
  • controlled study
  • treatment
  • mixed urinary incontinence
Source: 
http://dx.doi.org/10.1080/00016340500495058
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/13436
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.