You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15037
Title: 
Photoelastic Stress Analysis in Screwed and Cemented Implant-Supported Dentures With External Hexagon Implants
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1049-2275
Sponsorship: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conexao Sistemas de Protese
Sponsorship Process Number: 
FAPESP: 07/55061-3
Abstract: 
The aim of this study was to assess the stress distribution of the retention systems (screwed and cemented) for implant-supported fixed partial dentures by means of photoelastic method. Two models were made of photoelastic resin PL-2 with 2 implants (phi = 4.00 x 10 mm) located in the second premolar and molar region in each photoelastic model, varying the retention system (screwed and cemented). The implant-supported fixed partial dentures were standardized and made of Ni-Cr alloy. Axial and oblique (45 degrees) forces of 100 N were applied on the occlusal surface by means of a Universal Testing Machine (EMIC-DL 3000; Sao Jose dos Pinhais, Parana, Brazil). The results were observed and photographed in the field of a circular polariscope and qualitatively analyzed with the aid of computer software (Adobe Photoshop, San Jose, CA). The screw retention system presented the highest number of fringes when the loads were applied on the premolar, pontic, and molar and showed this behavior in all load applications, under axial and oblique loads. It was concluded that there was a better stress distribution and lower magnitude of stress on the cemented implant-supported dentures, under axial and oblique loads. Oblique load caused an increase in stress concentrations in all the models.
Issue Date: 
1-Jul-2010
Citation: 
Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 4, p. 1110-1113, 2010.
Time Duration: 
1110-1113
Publisher: 
Lippincott Williams & Wilkins
Keywords: 
  • Dental implant
  • fixed partial dentures
  • photoelastic stress analysis
  • screw retained
  • cement retained
Source: 
http://dx.doi.org/10.1097/SCS.0b013e3181e1b46e