You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15295
Title: 
Influence of Different Base Thicknesses on Maxillary Complete Denture Processing: Linear and Angular Graphic Analysis on the Movement of Artificial Teeth
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1049-2275
Abstract: 
Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.
Issue Date: 
1-Sep-2011
Citation: 
Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 22, n. 5, p. 1661-1665, 2011.
Time Duration: 
1661-1665
Publisher: 
Lippincott Williams & Wilkins
Keywords: 
  • Maxillary complete denture
  • acrylic resins
  • microwave
  • silicone
  • artificial tooth
Source: 
http://dx.doi.org/10.1097/SCS.0b013e31822e5d8c