Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16422
- Title:
- Adhesion strength characterization of PVDF/HA coating on cp Ti surface modified by laser beam irradiation
- Universidade Estadual de Campinas (UNICAMP)
- Universidade Estadual Paulista (UNESP)
- 0169-4332
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
- Up to the moment, there is no standardized test for measuring the adhesion strength of polymeric coatings on titanium substrate modified by laser beam irradiation. The present work aimed to assess the adhesion strength of polyvinylidene fluoride (alpha-PVDF)/hydroxyapatite (HA) composite coating on commercially pure titanium (alpha-cp Ti) substrate surface modified by laser beam irradiation, using the three-point bending test. The preparation of coating was carried out by mixing alpha-PVDF pellets dissolved in dimethylacetamide (DMA) with HA/DMA emulsion. The mixture was poured onto the alpha-cp Ti sample and left to dry in an oven. Commercially pure titanium plates were coated with alpha-PVDF/HA composite film, in proportions of 100/00 (PVDF) and 60/40 (PVDF/HA) in weight. The Ti-PVDF/HA samples were subjected to the three-point bending test and analyzed by scanning electron microscopy. According to the results, PVDF and PVDF/HA coatings showed a good adhesion strength on alpha-cp Ti surface, since no detachment was observed. (C) 2012 Elsevier B.V. All rights reserved.
- 1-Oct-2012
- Applied Surface Science. Amsterdam: Elsevier B.V., v. 258, n. 24, p. 10110-10114, 2012.
- 10110-10114
- Elsevier B.V.
- Polyvinylidene fluoride
- Hydroxyapatite
- Titanium
- Laser beam irradiation
- Coating
- Adhesion strength
- Biomaterial
- http://dx.doi.org/10.1016/j.apsusc.2012.06.084
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/16422
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.