You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25069
Title: 
Método da eletrorresistividade aplicado no monitoramento temporal da pluma de contaminação em área de disposição de resíduos sólidos urbanos
Other Titles: 
Electrical resistivity method applied in the temporal monitoring of the contamination plume in disposal area of urban solid waste
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1413-4152
Sponsorship: 
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Abstract: 
  • Este trabalho apresenta os resultados do monitoramento temporal da pluma de contaminação do aterro controlado de Rio Claro, São Paulo, por meio do método da eletrorresistividade, que consistiu na comparação dos resultados de várias seções de imageamento elétrico, executados nos mesmo locais, nos anos de 1999 e 2008. Zonas de baixa resistividade, com valores menores ou iguais a 50 Ω.m, foram associadas à contaminação por chorume. Desse modo, foi possível identificar dois sentidos do fluxo da pluma: (1) em direção ao sul, e (2) em direção ao oeste. Nas seções de 2008, a pluma de contaminação apresentou-se mais extensa e profunda do que em 1999. de forma complementar, as sondagens elétricas verticais aferiram a profundidade do nível freático e o sentido do fluxo d'água, subsidiando a interpretação dos imageamentos.
  • This paper shows the results of a periodical monitoring of the contamination plume of a controlled landfill in Rio Claro, São Paulo, Brazil, using electrical resistivity geophysical method. The monitoring consisted on comparing the results of several electrical sections, performed at the same location, in the years of 1999 and 2008. Low resistivity zones, with values lower than or equal to 50 Ω.m, have been associated to contamination by leachate. Thus, it was possible to identify two directions for the contamination flows: (1) toward south, and (2) toward west. In the results of 2008, the contamination plume was more extensive and profound than in 1999. The vertical electrical soundings indicated the water table depth and the water flow directions, helping the interpretation of results of the electrical profiles.
Issue Date: 
1-Dec-2010
Citation: 
Engenharia Sanitaria e Ambiental . ABES , v. 15, n. 4, p. 367-374, 2010.
Time Duration: 
367-374
Publisher: 
ABES
Keywords: 
  • sondagem elétrica vertical
  • imageamento elétrico
  • aterro
  • chorume
  • vertical electrical sounding
  • electrical profile
  • landfill
  • leachate
Source: 
http://dx.doi.org/10.1590/S1413-41522010000400009
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/25069
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.