You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25742
Title: 
Direct and Simultaneous Determination of Cd Cu, and Se in Blood Samples by Graphite Furnace Atomic Absorption Spectrometry
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Piaui Fed Univ
  • Universidade de São Paulo (USP)
ISSN: 
0195-5373
Sponsorship: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Abstract: 
A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO3 + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L-1 Pd(NO3)(2) + 3 mu L of 1000 mg L-1 Mg(NO3)(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L-1 Cd, 0.075 mu g L-1 Cu and 0.3 mu g L-1 Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L-1 Cd, 700 to 921.7 mu g L-1 Cu, and from 68.6 to 350 mu g L-1 Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.
Issue Date: 
1-Jul-2009
Citation: 
Atomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 30, n. 4, p. 115-119, 2009.
Time Duration: 
115-119
Publisher: 
Perkin-elmer Corp
Source: 
https://getinfo.de/app/Direct-and-Simultaneous-Determination-of-Cd-Cu/id/BLSE%3ARN256758001
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/25742
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.