You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25903
Title: 
Deposição eletrolítica catódica e anódica simultâneas para minimizar interferências de cobre e chumbo na determinação espectrofotométrica de cádmio em água e alimentos via reação com Verde de Malaquita e iodeto
Other Titles: 
Cathodic and anodic simultaneous electrolytic deposition to minimize copper and lead interferences on spectrophotometric determination of cadmium by the Malachite Green-iodide reaction
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0100-4042
Sponsorship: 
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Abstract: 
Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).
Issue Date: 
1-Dec-2001
Citation: 
Química Nova. Sociedade Brasileira de Química, v. 24, n. 6, p. 743-747, 2001.
Time Duration: 
743-747
Publisher: 
Sociedade Brasileira de Química
Keywords: 
  • flow spectrophotometry
  • cadmium
  • electrolytic precipitation
Source: 
http://dx.doi.org/10.1590/S0100-40422001000600006
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/25903
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.