You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/26147
Title: 
Optimization of photo-polymerized sol gel monolithic stationary phases prepared in polyacrylate-coated fused-silica capillaries for capillary electrochromatography
Author(s): 
Institution: 
  • Universidade Federal de Juiz de Fora (UFJF)
  • Universidade Federal de São João del-Rei (UFSJ)
  • Universidade Estadual Paulista (UNESP)
  • Univ Laval
ISSN: 
0026-265X
Sponsorship: 
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)
Sponsorship Process Number: 
  • CNPq: 400618/2004-4
  • CNPq: 154931/2006-3
  • CNPq: 476386/2007-1
  • FAPEMIG: EDT-161/05
  • FAPEMIG: 1906-5.02-07
Abstract: 
The preparation of photo-polymerized sol-gel monolithic stationary phases (MSP) within 100 mu m internal diameter polyacrylate-coated fused-silica capillaries for use in capillary electrochromatography (CEC) was optimized. Eight mixtures containing different amounts of methacryloxypropyltrimethoxysilane (MPTMS) as the polymeric precursor, hydrochloric acid solution as the catalyst, toluene as the porogen and bis(2,4,6-trimethylbenzoyl)-phenylphosphine oxide (Irgacure 819) as the photo-initiator were irradiated at 370 nm inside the capillaries in order to complete the MSP polymerization, according to a fractional factorial experimental design 2(IV)(4-1). All the preparation procedure, from capillary pretreatment until the MSP is ready to use in CEC, were made in less than four hours in mild conditions. A high pressurization injection device (HPID) useful for micro-volume syringes was built in order to achieve practical, controlled and precise injections of sols, solvents and electrolytes in the capillaries. The eight MSP were equally washed, conditioned and submitted to CEC procedures via short-end injection, which showed higher efficiency and peak height taking shorter analysis time. Electrochromatographic behaviors of the MSP were corroborated with morphological characterizations by scanning electron microscopy. The optimum condition, which allowed the separation of standard mixture containing thiourea (marker compound), naphthalene, acenaphthene, fluorene, phenanthrene and anthracene in twelve minutes without external pressure assistance, showed efficiencies up to 51,460 N/m, relative standard deviation from 0.05 to 3.3% for migration/retention time and from 0.14 to 1.6% for relative area (considering thiourea as an internal standard) and also showed no statistical evidence that three MSP prepared at the same condition are different within 95% confidence interval. (C) 2011 Elsevier B.V. All rights reserved.
Issue Date: 
1-Jan-2012
Citation: 
Microchemical Journal. Amsterdam: Elsevier B.V., v. 100, p. 21-26, 2012.
Time Duration: 
21-26
Publisher: 
Elsevier B.V.
Keywords: 
  • Capillary electrochromatography
  • Monolithic stationary phase
  • Short-end injection
  • Polycyclic aromatic hydrocarbons
  • Polyacrylate-coating fused-silica capillary
Source: 
http://dx.doi.org/10.1016/j.microc.2011.08.003
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/26147
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.