End-systolic pressure-diameter relation of the left ventricle during transient and sustained elevations of blood pressure
Other Titles: 
A elastância sistólica final do ventrículo esquerdo determinada durante elevações transitórias e elevações sustentadas da pressão arterial
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0066-782X
Abstract: 
OBJECTIVE: To assess the effect of transient and sustained variations in cardiac load on the values of the end-systolic pressure-diameter relation (ESPDR) of the left ventricle. METHODS: We studied 13 dogs under general anesthesia and autonomic blockade. Variations of cardiac loads were done by elevation of blood pressure by mechanical constriction of the aorta. Two protocols were used in each animal: gradual peaking and decreasing pressure variation, the transient arterial hypertension protocol (TAH), and a quick and 10 min sustained elevation, the sustained arterial hypertension protocol(SAH). Then, we compared the ESDR in these two situations. RESULTS: Acute elevation of arterial pressure, being it transitory or sustained, did not alter the heart frequency and increased similarly the preload and after load. However, they acted differently in end systolic pressure-diameter relation. It was greater in the SAH than TAH protocol, 21.0±7.3mmHg/mm vs. 9.2±1.2mmHg/mm (p<0.05). CONCLUSION: The left ventricular ESPDR values determined during sustained pressure elevations were higher than those found during transient pressure elevations. The time-dependent activation of myocardial contractility associated with the Frank-Starling mechanism is the major factor in inotropic stimulation during sustained elevations of blood pressure, determining an increase in the ESPDR values.
Issue Date: 
1-Jul-2000
Citation: 
Arquivos Brasileiros de Cardiologia. Sociedade Brasileira de Cardiologia - SBC, v. 75, n. 1, p. 26-32, 2000.
Time Duration: 
26-32
Publisher: 
Sociedade Brasileira de Cardiologia (SBC)
Keywords: 
  • end-systolic pressure-diameter relations
  • cardiac inotropism
  • arterial hypertension
Source: 
http://dx.doi.org/10.1590/S0066-782X2000000700003
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/26421
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.