You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27553
Title: 
Estudo comparativo para avaliação das falhas técnicas em radiografias convencionais de tórax
Other Titles: 
Comparative study to determine technical failures affecting conventional chest radiography
Author(s): 
Institution: 
  • Universidade de Mogi das Cruzes
  • Universidade Estadual Paulista (UNESP)
  • Hospital do Servidor Público Estadual Serviço de Doenças do Aparelho Respiratório
ISSN: 
0100-3984
Abstract: 
  • OBJETIVO: Especificar e quantificar as principais falhas técnicas, sejam elas eletrônicas ou mecânicas, presentes em radiografias convencionais de tórax, com o intuito de melhorar a sua qualidade e reduzir a necessidade da repetição dos exames e, consequentemente, a dose recebida pelo paciente. MATERIAIS E MÉTODOS: Foram selecionadas e avaliadas por um pneumologista 897 radiografias convencionais realizadas ou em projeção posteroanterior ou lateral em cinco instituições de saúde da cidade de São Paulo. em cada uma delas foram feitas análises das falhas técnicas presentes, as quais foram classificadas de acordo com o erro técnico radiográfico pré-definido e que levou à repetição do exame. RESULTADOS: Os resultados obtidos mostraram que o posicionamento incorreto do paciente (27%), a subexposição (23%) e a superexposição (15%) foram as principais falhas que contribuíram para a repetição dos exames e que apresentaram, na matriz de coeficiente de correlação Pearson, um erro acima de 0,7%, ocasionando aumento da dose recebida pelos pacientes. CONCLUSÃO: Os resultados observados indicaram a necessidade da realização de controle de qualidade dos aparelhos de raios X, a atenção do operador do equipamento, bem como outras abordagens para esclarecer o impacto da necessidade de repetição do exame.
  • OBJECTIVE: To specify and quantify main technical failures, whether mechanical or electronic, encountered at conventional chest radiography, in order to improve imaging quality, thus reducing the necessity of additional images acquisition and, consequently, the radiation dose received by the patients. MATERIALS and METHODS: A pulmonologist selected and reviewed 897 conventional chest radiographic films in either posteroanterior or lateral views, performed in five health institutions in the city of São Paulo. The films were individually analyzed in the search of technical failures, and classified according predefined technical radiographic errors which had led to re-examination. RESULTS: The obtained results have demonstrated that incorrect patient positioning (27%), underexposure (23%) and overexposure (15%) were the main failures contributing to repetition of examinations, with a Pearson correlation coefficient > 0.7%, thus leading to an increase in the dose received by the patients. CONCLUSION: The results of the present study indicate the need for X-ray apparatuses quality control, improvement of operators' skills, as well as further studies to clarify the impact resulting from examinations repetition.
Issue Date: 
1-Feb-2013
Citation: 
Radiologia Brasileira. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, v. 46, n. 1, p. 39-42, 2013.
Time Duration: 
39-42
Publisher: 
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
Keywords: 
  • Radiografias
  • Tórax
  • Pulmão
  • Falhas técnicas
  • Bioestatística
  • Radiography
  • Chest
  • Lung
  • Technical failures
  • Biostatistics
Source: 
http://dx.doi.org/10.1590/S0100-39842013000100012
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/27553
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.