You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27907
Title: 
Aferição da exatidão dos saquinhos plásticos, empregados na determinação da vazão de pulverizadores
Other Titles: 
Accuracy of graded polythene bags used for calibration of agricultural sprayers
Author(s): 
Matuo, T.
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0100-8358
Abstract: 
  • A utilização de sacos plásticos graduados para a medida da vazão de pulverizadores está ba stante di fundida entre técnicos e agricultores. 0 seu emprego é simples, consistindo, basicamente, em se coletar o líquido pulverizado por um bico durante o período equivalente ao deslocamento de 50 metros. O volume coletado é indicado numa escala graduada impr essa nos sacos calib rad ores e fornece diretament e a vazão em 1/ha. Firmas que comercializam os agro fármacos distribuem esses instrumentos aos agricultores, muitas vezes com propósitos puramente promocionais. Cinco sacos graduados de cada uma das 6 marcas diferentes foram aferidos. Agua a 20°C foi adicionada até as marcas de 100 1/ha, 250 1/ha e 400 1/ha. Esses volumes foram medidos em pro veta graduada e o volume real de pulverização foi calculado. Todos os saquinhos testados mostraram erros, em alguns bastante elevados, atingindo desvios de até 35,2%. Considerando esses resultados, é recomendada maior atenção na fabricação desses instrumentos. São sugeridas também algumas modificações da maneira de imprimir a escala e no conteúdo das instruções de uso.
  • The utilization of graded poly then e bags for meas urement of spray throught put is current practice among technicians and farmers. It s us e is very simple, basically, the liquid sprayed from one nozzle is collected during a period equivalent to run 50 meters. The volume collected is indicated on a scale printed on the bags with gives the spray volume in 1/ ha directly. Free sample of these plastic calibrators are distributed for promotional purpose by the pesticides companies. Five bags of each of 6 different brands were checked. Water at 20°C was filled in to the level of 100 1/ha, 250 1/ha and 400 1/ha. These volumes were meas ured in a standardized measuring cylinder and the actual spray volume calculated. Positive and negative errors of measure ment were found in all graded polithe ne bags. The largest error was 35,2% higher than the indicated mark. Considering these results one can recommend more accuracy in manufacturing such a device. It is also suggested modifications in printing graded scale and operating instructions.
Issue Date: 
1-Jun-1984
Citation: 
Planta Daninha. Sociedade Brasileira da Ciência das Plantas Daninhas , v. 7, n. 1, p. 65-69, 1984.
Time Duration: 
65-69
Publisher: 
Sociedade Brasileira da Ciência das Plantas Daninhas
Keywords: 
  • calibration
  • sprayer
  • pesticide application
  • calibração
  • Pulverizador
  • Pulverização
Source: 
http://dx.doi.org/10.1590/S0100-83581984000100008
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/27907
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.