Validity of hand-to-foot measurement of bioimpedance: Standing compared with lying position
Author(s): 
Institution: 
  • Auckland Univ Technol
  • Universidade Estadual Paulista (UNESP)
  • Loyola Univ
ISSN: 
1071-7323
Abstract: 
Objective: To assess the reliability of the standing measurement of hand-to-foot bioimpedance compared with measurements made in the lying position.Research Methods and Procedures: In 205 volunteers 6 to 89 years of age, 111 males and 94 females from six ethnic groups, effects of posture, time, and age on hand-to-foot resistance were studied over a range of body size. The effect of time in a position on resistance was also recorded in a small subset (n = 10), and repeat measurements over 3 days at the same time of the day were recorded in another subset (n = 12).Results: Lying impedance was consistently higher than standing, with the relationship (resistance lying/resistance standing) for the children (5 to 14 years) being 1.031, progressing to a ratio of 1.016 in those >60 years. The time spent static in either position did change resistance measurements - a decrease of up to 9 Omega (mean 5 Omega, 1.0%) over 10 minutes of standing and an increase of up to 7 Omega (mean 3 Omega, 0.7%) with lying.Discussion: In the field, measurements of hand-to-foot bioimpedance can be made in the standing position, and, with appropriate adjustment, previously validated recumbent equations can be used. Given that errors in the measurement of height and weight also affect the reliability of the derivation of body fat from bioelectrical conductance, the errors that may arise from a more practical standing measurement rather than lying are minimal.
Issue Date: 
1-Feb-2006
Citation: 
Obesity. Silver Spring: North Amer Associação Study Obesity, v. 14, n. 2, p. 252-257, 2006.
Time Duration: 
252-257
Publisher: 
North Amer Associação Study Obesity
Keywords: 
  • single frequency bioimpedance analysis
  • position
  • lying
  • standing
  • correction factor
Source: 
http://dx.doi.org/10.1038/oby.2006.32
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/31740
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.