Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/39237
- Title:
- Power flow in four-wire distribution networks - General approach
- Universidade Estadual Paulista (UNESP)
- 0885-8950
- The neutral wire in most power flow software is usually merged into phase wires using Kron's reduction. Since the neutral wire and the ground are not explicitly represented, neutral wire and ground currents and voltages remain unknown. In some applications, like power quality and safety analyses, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of special interest. In this paper, a general power flow algorithm for three-phase four-wire radial distribution networks, considering neutral grounding, based on backward-forward technique, is proposed. In this novel use of the technique, both the neutral wire and ground are explicitly represented. A problem of three-phase distribution system with earth return, as a special case of a four-wire network, is also elucidated. Results obtained from several case studies using medium- and low-voltage test feeders with unbalanced load, are presented and discussed.
- 1-Nov-2003
- IEEE Transactions on Power Systems. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc., v. 18, n. 4, p. 1283-1290, 2003.
- 1283-1290
- Institute of Electrical and Electronics Engineers (IEEE)
- distribution networks
- earth return
- power flow
- three-phase four-wire
- unbalance
- http://dx.doi.org/10.1109/TPWRS.2003.818597
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/39237
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.