Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/63485
- Title:
- Coronary perfusion pressure as a determinant of ventricular performance
- Universidade Estadual Paulista (UNESP)
- 0014-4754
- The results observed in this work support the view that coronary perfusion pressure affects ventricular performance independently of metabolic effects; a mechanism operating in beat-to-beat regulation is proposed.
- 1-Dec-1980
- Experientia, v. 36, n. 8, p. 974-975, 1980.
- 974-975
- animal experiment
- coronary artery blood flow
- dog
- heart
- heart ventricle contraction
- isolated heart
- Animal
- Blood Pressure
- Coronary Vessels
- Dogs
- Heart
- In Vitro
- Perfusion
- Support, Non-U.S. Gov't
- http://dx.doi.org/10.1007/BF01953828
- Acesso restrito
- outro
- http://repositorio.unesp.br/handle/11449/63485
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.