You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/69872
Title: 
Electromyographyc evaluation of movements of lower limb in double pulley system equipment: Comparison between gastrocnemius (caput laterale) and gluteus maximus
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
0301-150X
Abstract: 
It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.
Issue Date: 
1-Sep-2007
Citation: 
Electromyography and Clinical Neurophysiology, v. 47, n. 6, p. 293-299, 2007.
Time Duration: 
293-299
Keywords: 
  • Double pulley
  • Electromyography
  • Gastrocnemius
  • Gluteus Maximus
  • abduction
  • adduction
  • adult
  • controlled study
  • electrode
  • electromyography
  • gastrocnemius muscle
  • gluteus maximus muscle
  • hip
  • human
  • human experiment
  • kinesiology
  • knee function
  • limb movement
  • male
  • muscle action potential
  • muscle contraction
  • myoelectricity
  • normal human
  • weight lifting
  • Adolescent
  • Adult
  • Exercise Test
  • Hip Joint
  • Humans
  • Knee Joint
  • Male
  • Movement
  • Muscle Contraction
  • Muscle, Skeletal
  • Range of Motion, Articular
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/69872
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.