Abstract: 
This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.
Issue Date: 
29-Sep-2008
Citation: 
PESC Record - IEEE Annual Power Electronics Specialists Conference, p. 4290-4295.
Time Duration: 
4290-4295
Keywords: 
  • Cooling
  • Electric inverters
  • Induction motors
  • Land vehicle propulsion
  • Topology
  • Wave filters
  • Cascaded multilevel inverters
  • Cooling system design
  • First orders
  • Multi-level inverters
  • Neutral point clamped inverters
  • Output filtering
  • Performance indexes
  • Power losses
  • Total Harmonic Distortion
  • Power electronics
Source: 
http://dx.doi.org/10.1109/PESC.2008.4592632
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/70590
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.